The choice of beam angle depends on the installation height and the desired illumination area.
Narrow beam angle (60° or less): Suitable for high ceilings (8–15 meters). The light is concentrated downward, providing high central illuminance—ideal for illuminating specific zones or machinery. However, because the coverage area is small, more fixtures will be required.
Medium beam angle (90°–110°): The most common choice, suitable for heights of 6–10 meters. It offers a good balance between central illuminance and coverage area.
Wide beam angle (120° or greater): Suitable for lower ceilings (4–6 meters). The light spreads out evenly, preventing the formation of "hot spots" (bright patches) on the floor. For exceptionally high spaces (>15 meters), an ultra-narrow beam angle—40° or even less—may be required.
Practical selection guide: The relationship between installation height (H) and the diameter of the illuminated area (D) is defined by the formula: tan(θ/2) = D/(2H). For example, if H = 10m and you want D = 15m, then θ = 2 × arctan(7.5/10) = 2 × 36.9° ≈ 74°; in this case, a 90° lens would be a suitable choice.
In practice, you can opt for fixtures with interchangeable lenses, allowing you to determine the optimal beam angle through on-site testing.