How is the nighttime lighting performance of high-mast lights evaluated?

Evaluating the nighttime lighting performance of high-mast lights requires on-site measurements based on the following indicators:

1.  Horizontal Illuminance: Arrange measurement points in a grid pattern (e.g., 10m × 10m) on the target ground area. Use an illuminance meter to measure values ​​and calculate the average, minimum, and maximum illuminance, as well as the uniformity ratio U2 (minimum/average).

2.  Vertical Illuminance: For locations requiring the identification of vertical objects (such as container serial numbers), vertical illuminance must also be measured (at a height of 1.5 meters above the ground).

3.  Glare: Use a luminance meter to measure the luminance of the luminaires within the field of view and calculate the Glare Rating (GR). Alternatively, employ a subjective evaluation method: observe the lighting from various angles and record whether it causes glare or visual discomfort.

4.  Color Temperature and Color Rendering: Use a spectrometer to measure color temperature and Color Rendering Index (CRI) to verify compliance with design specifications.

5.  Flicker: Use a mobile phone or high-speed camera to record the light and observe whether visible flickering occurs.

6.  Shadows: Observe whether there are significant shadowed areas, particularly in the zones where light beams from multiple luminaires overlap.

7.  Light Pollution: Measure vertical illuminance or illuminance levels at nearby sensitive locations (such as residential windows) and compare the results against local light pollution standards. Evaluations should be conducted after the luminaires have stabilized (typically 30 minutes after switching on LEDs). If measured values ​​deviate from design values ​​by more than ±20%, the luminaire angles or power output should be adjusted. Finally, a lighting inspection report should be issued to serve as the basis for acceptance.

prev
How is lightning protection and grounding implemented for high-mast lights?
Is professional qualification required for the installation of high-mast lights?
next
recommended for you
Get in touch with us
16+years Professional industrial lighting manufacturer, committed to provide high quality lighting products and systematic lighting solutions for global customers
Contact Us
Add:
No. 1199, ZhenNan Road, Putuo District, Shanghai, China.


Contact person: David Yuan
Tel: +86 - 21 - 6250 7355
WhatsApp: +86 17721074459
Copyright © 2026 Shanghai Jing Rui Lighting Co., Ltd. | Privacy Policy Sitemap

Get the latest catalog and price list

弹窗效果
Customer service
detect